 |
Annunciator Visual/Audio Alarm Panel
Annunciator Visual/Audio Alarm Panel
Product Description:
The 24 VDC annunciator panel allows for 10 switch inputs to light up separate alarm areas via LED lights. Audible and visual alarm components shall act as a warning system to indicate trouble and alarm situations with silence capabilities. These alarms are be triggered to simulate fire/trouble for each floor or room via toggle switches. In order to simulate fire/trouble situations a separate instructor box is used to switch on the annunciator panel's indicator lights/alarm to allow the trainee to determine which area is in need of aid, similar to control rooms in larger buildings. Control box components shall consist of a 12" x 10" x 6" NEMA 12 enclosure, 120 VAC to 24 VDC transformer, terminal block, 10 toggle switch with boots. 120 VAC electrical service, component assembly, and wiring materials are by others.
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|
|
Balcony, Cantilevered
Balcony, Cantilevered
Product Description:
Constructed of prime painted structural tube and hot-dipped galvanized bar grate deck and joists. Can be ordered in a variety of lengths and at nearly any deck level.
Application for use:
Gives specialized training in laddering, hose advancement and rappelling.
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Balcony, Inset
Balcony, Inset / Corner
Product Description:
Recessed inset/corner balcony on nearly any floor(s) with 1.25"I.D. (I.55"O.D.) schedule 40 hot-dipped galvanized round pipe perimeter railings and access door to interior.
Application for use:
Provides a recessed balcony for rappelling and laddering exercises. Gives similar live fire experiences encountered in motel balconies and condominiums.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Balcony, Open Corner
Balcony, Open Corner
Product Description:
Can be added to any tower model that offers enough floor space to accommodate this option.
Application for use:
Provides the ability to perform rescue scenarios appropriate for motel and condominium fires.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Balcony, Supported
Balcony, Supported
Product Description:
Supported balcony to second deck level. Deck size is 3'6'' wide x 6' long and includes a swing door at the balcony level. Constructed of tubular columns and 1.25" I.D. (1.66' O.D.) schedule 40 round pipe railings. Hot dipped galvanized.
Application for use:
Gives specialized training in laddering, hose advancement and rappelling.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Basement Trainer
Basement Trainer
Product Description:
A 4' x 8'-6" balcony is installed above the gooseneck of a fire training trailer with a perimeter railing and a removable exterior ladder. A fixed interior stair is included from the balcony into the burn room. The exterior ladder, perimeter railing and interior stair are hot-dipped galvanized.
Application for use:
Available for Fire Facilities' Mobile Trainee to simulate basement fire scenarios.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burn Area, Attic
Burn Area, Attic
Product Description:
4' x 4' area consisting of three walls, the floor, and ceiling lined with the WestecTM Insulation System. Fires are limited to 600°F.
Application for use:
Provides an excellent fire location in the attic offering variety in training scenarios.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burn Area, Corner
Burn Area, Corner
Product Description:
8' x 8' area can be designed in nearly any inside corner of any Fire Facilities training tower. Fires are limited to 600° F. Floor protection supplied by others.
Application for use:
Provides excellent second and third fire locations that offer a variety of training scenarios. Appropriate for trash can style fires.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burn Crib
Burn Crib
Product Description:
The 49" x 49" burn prop elevates the fuel source of Class A fires approximately 6" above the floor. Easily bolts together and consists of 12-gauge galvanized materials.
Application for use:
Provides a convenient means of protecting concrete floors from premature spalling and cracking.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burn Room
Burn Room
Product Description:
12' x 12' room with two doors. Walls, ceiling, doors and shutters are protected with the WestecTM Insulation System. Floor protection supplied by others.
Application for use:
Provides the ability to conduct live fire training. May be used as a second burn room to add flexibility to training scenarios.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Class A Burn Prop
Class A Burn Prop
Product Description:
30" W x 50" L x 36" H, constructed of 1/8" stainless steel weighing 300 pounds. Includes large handles and heavy steel locking casters for easy relocation.
Application for use:
Holds the fire 18" above the floor to protect the floor surface and contains the fuel pile; eliminates the scattering of unburned fuel and reduces clean up.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Class A Burn Prop - Bed Simulator
Bed Simulator - Class A Burn Prop
Product Description:
The bed simulator assembly consists of 1/4" thick prime painted angles and 12 gage stainless steel panels bolted together with 3/8" diameter bolts through pre-punched holes for ease of assembly. The prime painted 19W4 x 1 1/2" x 3/16" bar grate is designed to hold class "A" materials 1'-4" above the floor surface. Dimensions for this prop shall be approximately 4'-5 1/2" x 4'-5 1/2" x 4'-4" tall and shall resemble a bed with headboard. A sliding/removable stainless steel lid with large ventilation holes shall also be provided. The lid helps to limit the number of pallets trainees can place in the unit by covering approximately half of the entire unit. See drawings for quantities required. 534.68 lbs.
|
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|
|
Class A Burn Prop - Bunk Bed Simulator With Enclosed Top Bunk
Bunk Bed Simulator With Enclosed Top Bunk - Class A Burn Prop
Product Description:
The bunk bed simulator assembly consists of 1/4" thick prime painted angles and 12 gage stainless steel panels bolted together with 3/8" diameter bolts through pre-punched holes for ease of assembly. The prime painted 19W4 x 1 1/2" x 3/16" bar grate is designed to hold class "A" materials 1'-4" above the floor surface. Dimensions for this prop shall be approximately 4'-5 1/2" x 4'-5 1/2" x 6'-7" tall and shall resemble a bunk bed. The overhead bunk of this unit is also 4'-5 1/2" x 4'-5 1/2" and is enclosed by stainless steel panels. See drawings for quantities required. 859.40 lbs.
|
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|
|
Class A Burn Prop - Bunk Bed Simulator With Burnable Top Bunk
Bunk Bed Simulator With Burnable Top Bunk - Class A Burn Prop
Product Description:
The bunk bed simulator assembly consists of 1/4" thick prime painted angles and 12 gage stainless steel panels bolted together with 3/8" diameter bolts through pre-punched holes for ease of assembly. The prime painted 19W4 x 1 1/2" x 3/16" bar grate is designed to hold class "A" materials 1'-4" above the floor surface. Dimensions for this prop shall be approximately 4'-5 1/2" x 4'-5 1/2" x 6'-7" tall and shall resemble a bunk bed. The overhead bar grate bunk of this unit is also 4'-5 1/2" x 4'-5 1/2" and provides another area to hold class "A" materials for a secondary fire. See drawings for quantities required. 951.70 lbs.
|
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|
|
Class A Burn Prop - Stove Simulator With Enclosed Overhead Hood
Stove Simulator With Enclosed Overhead Hood - Class A Burn Prop
Product Description:
The stove simulator assembly consists of 1/4" thick prime painted angles and 12 gage stainless steel panels bolted together with 3/8" diameter bolts through pre-punched holes for ease of assembly. The prime painted 19W4 x 1 1/2" x 3/16" bar grate is designed to hold class "A" materials 1'-4" above the floor surface. Dimensions for this prop shall be approximately 4'-5 1/2" x 4'-5 1/2" x 6'-7" tall and shall resemble a commercial grade stove. The overhead hood of this unit is 2'-11" x 4'-5 1/2" and is enclosed by stainless steel panels. A sliding/removable stainless steel range top with large ventilation holes shall also be provided. The range top helps to limit the number of pallets trainees can place in the unit by covering approximately half of the unit. See drawings for quantities required. 829.53 lbs.
|
 |
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Class A Burn Prop - Stove Simulator With Overhead Burn Hood
Stove Simulator With Overhead Burn Hood - Class A Burn Prop
Product Description:
The stove simulator assembly consists of 1/4" thick prime painted angles and 12 gage stainless steel panels bolted together with 3/8" diameter bolts through pre-punched holes for ease of assembly. The prime painted 19W4 x 1 1/2" x 3/16" bar grate is designed to hold class "A" materials 1'-4" above the floor surface. Dimensions for this prop shall be approximately 4'-5 1/2" x 4'-5 1/2" x 6'-7" tall and shall resemble a commercial grade stove. The overhead bar grate hood of this unit is 2'-11" x 4'-5 1/2" and provides another area to hold class "A" materials for a secondary fire. A sliding/removable stainless steel range top with large ventilation holes shall also be provided. The range top helps to limit the number of pallets trainees can place in the unit by covering approximately half of the unit. See drawings for quantities required. 898.44 lbs.
|
 |
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Confined Space Rescue Prop
Confined Space Rescue Prop
Product Description:
The 36" diameter corrugated galvanized pipe extends from the first floor to the second floor. It features a 90 degree elbow for the ultimate in confined space training. The 3' x 3' Milcor floor door at the top provides access into the prop and to the first floor.
Application for use:
An excellent way to simulate restricted environments including collapsed structures, teach trainees how to negotiate small openings, and test physiological capabilities.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Confined Space Vertical Rescue Prop, Removable
Confined Space Vertical Rescue Prop, Removable
Product Description:
This removable prop consists of four movable wall panels and a Milcor floor door. The panels are configured to form a vertical shaft. At the top of the shaft is a 3' x 3' Milcor floor door that provides access into the prop from the floor above. The floor door is equipped with counter balancing springs and is prime painted. Each of the four 3'7"W x full ceiling height wall panels are constructed of 20-gauge galvalume vertical and horizontal channel stiffeners which attach to a 14-gauge galvalume hanging track. The whole system is then held in place with two compression clamps.
Application for use:
The functionality of the movable panels allow the prop to be assembled for confined space training and removed when training is needed in the entire room. The prop can be installed on any level of a two-story or taller training tower as well as on multiple levels for the ultimate in confined space training.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Debris Catch Pan
Debris Catch Pan
Product Description:
42" W x 33" L x 5" H 16-gauge galvanized catch pan features weep holes for drainage, latches on each side for easy attachment and removal from the structure, and four handles for moving.
Application for use:
Collects material left over from the fire fuel source (i.e. nails, unburned wood scraps, etc.) for easy disposal as the room is cleaned and hosed out through an exterior burn room door.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DurabakTM Slip-Resistant Paint Roof System
Durabak™ Slip-Resistant Paint Roof System
Product Description:
18-gauge galvanized roof panels are covered with a three-coat paint system providing a safe, long-lasting roof system. The basecoat is an etch primer while the two topcoats are polyurethane paint with embedded rubber aggregate.
Application for use:
Provides an abrasion, chemical, saltwater, UV, corrosion, and slip-resistant surface to practice safe training during roofing exercises. In addition, the system is waterproof to ensure tower protection at all times.
Note: Paint does not cover recesses in panels, only the flat portion of the panels. Durabak is a trademark of The Durabak Company.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Slip-Resistant Roof Tape
Slip-Resistant Roof Tape
Product Description:
4" wide slip-resistant tape can be applied to 18-gauge galvanized roof panels for added safety. The tape, with pressure-sensitive adhesive, features a mineral coated surface for light to heavy foot traffic. The acceptable manufacturer of this tape is 3M.
Note: Tape should only be applied to the flat portion of the roof panels.
Application for use:
Recommended for smaller areas only, the tape provides a slip-resistant surface to practice safe training during roofing exercises.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Elevator Shaft (Confined Space)
Elevator Shaft (Confined Space)
Product Description:
Offered in many heights and includes roll-up door access to the shaft at each floor. The roof of the tower can be equipped with a hatch for vertical work.
Application for use:
Offers real-life training in confined space while providing emergency access to the trainees along the vertical drop.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Exhaust Fan
Exhaust Fan
Product Description:
Available as: 208-volt, 3-phase, 2-speed or 240-volt, single-phase, single-speed units. Both models feature a 1 1/2 horsepower electric motor and a belt driven, centrifugal wall-mounted fan. The maximum output of both units is 8,000 cubic feet per minute.
Application for use:
Circulates heat and smoke and evacuates towers quickly.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Exterior Stairs (Fire Escape)
Exterior Stairs (Fire Escape)
Product Description:
Stair widths are 3'-0" wide and hot-dipped galvanized. The assembly is manufactured from formed stringers welded to bar grate treads with open risers. The railing system is constructed from welded tube steel. Hand rails manufactured from 1.25"I.D. (1.66" O.D.) schedule 40 round pipe. Includes swing doors at each upper floor. The exterior stairs or fire escape can be ordered to fit any level.
Application for use:
Provides a second means of egress off a floor, aids in simultaneous scenarios, and gives the opportunity to train in advancement down stairs, simulating a basement fire.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Facade, Mortarless Brick
Facade, Mortarless Brick
Product Description:
Motarless brick siding can be attached to the outside of any Fire Facilities training tower. Novabrik® is the approved manufacturer of the mortarless brick facade.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Firefighter Combat Challenge Stair Tower
Firefighter Combat Challenge Stair Tower
Product Description:
Designed to the same specifications as the Scott Firefighter Combat Challenge®. This 41'H x 12'L standalone structure is hot-dipped galvanized. Stair tower can be connected to new or existing fire training facility or placed as a stand alone unit. Star widths are 2'6" wide and constructed of formed stringers welded to bar grate treads with open risers. Hand rails manufactured from 1.25" I.D. (1.66" O.D.) schedule 40 round pipe.
Application for use:
Offers training in hose advancement, preparation for national competition, as well as a venue for physical conditioning.
|
Bought as stand alone accessory |
|
|
|
|
|
Floor Door
Floor Door
Product Description:
Flush-mounted, single-leaf door is all-steel constructed with ĵ" tread plate covers, stainless steel hinges, and torsion springs. Door includes a snap latch with a removable handle. Various sizes available.
Application for use:
Provides confined space access to the floor below and supports full floor loads. Rated for 300 psf.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Foldable Roof Guard Rail
Foldable Roof Guard Rail
Product Description:
Sturdy 42" high railing system manufactured from 1.25" I.D. (1.66" O.D.) schedule 40 round pipe and hot-dipped galvanized. Installed around the perimeter of the roof and folds down for easy transport.
Application for use:
Chain gates provide safety during laddering, hose advancement, and rappelling exercises.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Forcible Entry Door
Forcible Entry Door
Product Description:
Heavy-duty steel door equipped with a breakaway lock mechanism. Lock system is easily reset and force requirements are adjustable. Approved manufacturer of lock mechanism is Power Jamb.
Application for use:
Provides training for breaching a locked door.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Helicopter Skid Simulator
Helicopter Skid Simulator
Product Description:
6' x 5' 11" 18-gauge roof deck simulates a helicopter floor. Constructed of prime painted structural tube and pipe to form skids, hot-dipped galvanized joists, and positioned on the tower roof. Simulator is totally cantilevered. Perimeter railing is 1.25" I.D. (1.66" O.D.) schedule 40 hot-dipped galvanized round pipe with chained gates on both sides.
Application for use:
Provides realistic airborne insertion exercises without the expense of flight time and added danger of prop-wash.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ladder Hook Bar
Ladder Hook Bar
Product Description:
The ladder hook bar consists of 10' 6" long schedule 80 pipe with 12-gauge pipe angles for attachment. The system is hot-dipped galvanized.
Application for use:
The bar is used on sloped roofs to ensure a safe attachment of the trainee's ladder hook when resting the ladder against the roof.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ladder, Caged
Ladder, Caged
Product Description:
The ladder is constructed of tubular rails and bar steps, with a cage is made from flat steel strapping. The entire unit is hot-dipped galvanized. The ladder extends from the ground level to the roof.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ladder, Interior
Ladder, Interior
Product Description:
Constructed of tubular rails and bar steps. Also included is a railing system with a chain gate at the upper floor. All surfaces are hot-dipped galvanized.
Application for use:
Allows access to attic or roof areas and offers training in advancing equipment vertically in a confined area.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ladder, Ship's
Ladder, Ship's
Product Description:
Heavy-gauge steel stringers welded to bar grate treads. Also included is a tubular railing on both sides. All components are hot-dipped galvanized.
Application for use:
Offers more convenient access to roofs or other remote areas.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Manhole Frame/Cover
Manhole Frame/Cover
Product Description:
A 34" solid cast iron manhole cover with self sealing gasket shall be used to access floor below. A surrounding cast iron square base/frame shall be provided along with a concealed pick point in the cover.
|
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|
|
Movable Wall System/Maze
Movable Wall System/Maze
Product Description:
3'7"W x full ceiling height panels are constructed of 20-gauge galvalume vertical and horizontal channel stiffeners which attach to a 14-gauge galvalume hanging track. The whole system is then held in place with two compression clamps to create a maze.
Application for use:
The system can be easily slid, moved, and removed, without the use of tools, to create a variety of room configurations for an enhanced training experience. Patent US 6,889,473 B2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Movable Half Wall System/Maze
Movable Half Wall System/Maze
Product Description:
Each individual movable wall panel (36" wide x 45" tall x 1 5/8" thick) is constructed of 20 gauge galvanized vertical stiffeners and 16 gauge galvanized horizontal channels. The upper and lower horizontal channels allow for attachment of other wall panels to any point along either side of this panel or to either end. The whole system is self standing and allows the instructor to view trainees maneuvering the maze.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Movable Wall System/Maze with Working Door
Movable Wall System/Maze with Working Door
Product Description:
Constructed of the same durable materials as our Movable Wall System/Maze, this system features a 2'6" W x 6'10" H door. The 20-gauge galvanized steel door allows entry into the partitioned area for enhanced training. The included lockset allows instructors to secure the area before and after training.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Multi-Level Platform
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Open Story
Open Story
Product Description:
One or more open stories can be provided on any of the training towers. The lowest open floor is guarded with a parapet wall and the roof as well as any upper open stories is guarded with a hot-dipped galvanized railing system.
Application for use:
Allows for a number of laddering, rappelling and balcony rescue exercises.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating Lever Latch
Operating Lever Latch
Product Description:
Heavy-duty latch opens shutters and doors from either side. Latch case is constructed of 1/8" thick zinc plated steel with a black powder coated finish.
Application for use:
Interior and exterior handles may be padlocked to secure tower when not in use. The latch's hasp secures lever in place.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Propane System (supplied by others)
Propane System (supplied by others)
Product Description:
Propane (or natural gas) props can be configured to resemble many appliances or furniture types. Each prop is capable of producing multiple fire situations.
Application for use:
Propane systems offer a cleaner burning environment, friendly fire with faster recover times, and minimal cleanup.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rappel Railing
Rappel Railing
Product Description:
The 42" high, prime-painted rappel railing system consists of three 3" diameter, Schedule 80 pipes which are installed horizontally 12" on center.
Application for use:
The system allows the rope to run from the rappelling ring tie off on the deck, over the railing to the trainee. Used to aid trainees in rappelling exercises by raising the rope off the roof deck to help with the initial descent.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rappelling Anchor, Swivel
Rappelling Anchor, Swivel
Product Description:
Can be added to any floor or roof deck or mounted overhead. Rated for a working load limit of 5,000 pounds (OSHA load compliant per 1926.502(d)(15). The anchor housing is constructed of aircraft quality galvanized alloy and capable of a 360-degree swivel and 180-degree pivot. To ensure the safety of trainees, each anchor is 200% proof-load tested.
Application for use:
Rappelling exercises can be used to simulate high-angle rescue, helicopter deployment, or raising a victim or equipment.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rappelling Platform
Rappelling Platform
Product Description:
Constructed of prime painted structural tube, hot-dipped galvanized joist sections and bar grate. Welded steel tube rails, also hot-dipped galvanized, are optional. Features a 100 PSF deck live load and can be ordered in a variety of lengths and at nearly any deck level.
Application for use:
Provides a cantilevered platform for freefall-style rappelling.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Riser System (Fire Department Connection)
Riser System (Fire Department Connection)
Product Description:
Includes a brass siamese fire department connection on the building's exterior, a 4" diameter galvanized riser, a connection on the building's interior at each deck level and a connection for sprinklers at each floor. Sprinkler system is not included.
Application for use:
Simulates experiences that are likely to be encountered on real-life calls.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Roll-up Door
Roll-up Door
Product Description:
A continuously corrugated galvanized steel curtain with a siliconized polyester finish. The door slides on guides to a top drum through the means of a torsion spring.
Application for use:
Aids in the simulation of commercial training exercises through a larger access door.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof Hatch (3' x 2'6")
Roof Hatch (3' x 2'6")
Product Description:
Bilco roof hatches are galvanized and prime painted and are equipped with counter balancing springs and shock absorbers.
Application for use:
Appropriate size for a roof ladder.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Roof Hatch (2'6" x 4'6")
Roof Hatch (2'6" x 4'6")
Product Description:
Bilco roof hatches are galvanized and prime painted and are equipped with counter balancing springs.
Application for use:
Appropriate size for a ship's ladder.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Scout Temperature Monitoring System
Scout Temperature Monitoring System
Product Description:
Provides real-time data of nine heat monitoring probes simultaneously, allowing the trainer to immediately adjust the training scenario should unsafe conditions exist.
The software interfaces with PCs via a handheld infrared data transfer device, offering a smooth transfer and storage of training data. Click here to view example temperature readings in Excel format. Permanent records can be used for personnel files as well as evaluations for ISO classification. The battery-powered Scout features touch-sensitive display and controls, advanced data logging capabilities including the storage of 72 hours of training data, internal and external alarms, and Windows compatible data software. The Scout is supported by a one-year warranty.
Application for use:
Provides a convenient and functional method of obtaining temperatures and storing data to ensure safe live fire training.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Scout External Alarm
Scout External Alarm
Product Description:
Audible and visual external alarm components connect to Scout Temperature Monitoring System. Buzzer (85 decibels at 10 feet) and amber strobe light notify the trainer when burn room temperatures exceed predetermined trip limits. Alarm components include a 24 VAC transformer, relay, momentary kill switch/button, and a NEMA 3R metal enclosure. 120 VAC electrical service and component assembly required.
Application for use:
Ensures safe live fire training by providing a hands-free warning when pyrometer's trip limits have been surpassed.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Scout External Alarm Horn
Scout External Alarm Horn
Product Description:
External audible alarm upgrade to the Scout External Alarm features an adjustable 78-103 decibel level and has a 120 VAC electrical service. Weather rating is NEMA 4x.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Smoke Distribution System
Smoke Distribution System
Product Description:
Consists of a piping system controlled by gate valves that will service up to 6 rooms, a circulation fan, 3" diameter schedule 40 PVC pipes and cabinet. Requires a smoke generator (sold separately).
Application for use:
Directs the output of a smoke generator (not included) to any of the serviced floors.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Smoke Generator
Smoke Generator
Product Description:
Operates on a 100% duty cycle with a smoke output of 7,680 cfm. This generator shall use
an oil based fluid with a maximum particle size of .7 microns to ensure long hang
time and dense smoke (maximum visibility of 3 ft in a 29' x 29' x 9' high area after
one minute of use). An automatic purging system shall be included to
prevent the heat exchanger from premature failure and clogs. The generator
shall include 4 gallons of a safe, nontoxic, and oil based fluid. Oil based fluids
are recommended for fire training environments, over water based fluids, as oil based f
luids have 20 to 25 times longer hang time and will not dissipate rapidly in high temperature
environments. The smoke generator shall have a 5 year warranty.
Application for use:
Used with Smoke Distribuition System. Produces a dense, white smoke.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sprinkler System
Sprinkler System
Product Description:
Standard sprinkler configurations can be provided to any levels or rooms.
Application for use:
Simulates experiences that are likely to be encountered on real-life calls.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tactical Breach Door
Tactical Breach Door
Product Description:
The tactical breach door provides training for ram/kick breaching and shotgun breaching. The door frame and backer frame shall be AR-500 steel. The door shall have an easily replaceable plywood façade such that replacement can be accomplished using standard hand tools. The door shall have two interchangeable mechanical breaching mechanisms which can simulate standard locks/deadbolts or multiple locking mechanisms. These mechanisms shall be easily reset (mechanically) and the force requirements are adjustable. The door shall also have an easily replaceable consumable breachpoint for use with shotgun breaching. The mechanical breaching mechanism may be used in tandem with the consumable breachpoint to simulate multiple lock situations. (See drawings for quantities required)
|
 |
; |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|
|
Westemp® Insulating Panels
Westemp® Insulating Panels
Product Description:
4' x 4' x 1" thick non-asbestos, incombustible panels combine structural strength with high thermal insulating values. Westemp is not subject to thermal shock and offers low moisture absorption, providing protection to a continuous burn of 1200° F.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|